fabed_posts

Ardel Power Posts

Ardel Power Posts are a custom adjustable post solution engineered for your needs.

From standard residential needs, crawlspace's, decks, or temporary supports.

Ardel Power Posts, when engineered with a steel beam, can offer significant span options, reducing obstructions.

We can help you!

Ardel Power Posts

CAPACITY (LBS)
HEIGHT
Post A
Post B
Post C
Post D
4' OR LESS
19,500
31,500
43,500
63,000
4'1" - 8'0"
19,500
31,500
43,500
63,000
8'1" - 9'0"
16,000
27,500
43,500
63,000
9'1" - 10"0"
14,000
23,500
43,500
63,000
10'1" - 11'0"
11,500
20,500
38,000
56,000
11'1" - 12'0"
9,500
18,000
32,000
49,000
4' OR LESS
Post A: 19,500
Post B: 31,500
Post C: 43,500
Post D: 63,000
4'1" - 8'0"
Post A: 19,500
Post B: 31,500
Post C: 43,500
Post D: 63,000
8'1" - 9'0"
Post A: 16,000
Post B: 27,500
Post C: 43,500
Post D: 63,000
9'1" - 10"0"
Post A: 14,000
Post B: 23,500
Post C: 43,500
Post D: 63,000
10'1" - 11'0"
Post A: 11,500
Post B: 20,500
Post C: 38,000
Post D: 56,000
11'1" - 12'0"
Post A: 9,500
Post B: 18,000
Post C: 32,000
Post D: 49,000
beam_and_post_display
powerposts1

Power Post Ordering Notes

To ensure you receive the correct  Power Posts  for your project we require:

1. The load requirements (supplied by engineer or truss manufacturer)
2. The size of the opening (dimension "H on the diagram)

Ardel stocks  Power Posts in 2" increments, (ex. 8'2" - 8'4", 8'4" - 8'6" etc.) These heights represent the size of opening they will fit while still allowing about 2" of adjustment either way. This means an 8'2" - 8'4"  Power Posts will bottom out at 8'0" and top out at 8'6".

  • Ardel Power Posts are certified to a maximum height of 12'0"
  • Stamped engineer drawings are available upon request
powerposts5

Power Posts Installation Notes

  •  Power Posts A & C require a 1-1/2" wrench to adjust
  •  Power Posts  B & D require a 1-7/8" wrench to adjust
  • The  Power Post must be within 1/2" of vertical to meet the designed carrying capacity
  • It is possible to screw the  threaded rod  out of the  Power Post so it is very important to order the right Power Post for the right size opening provide an accurate opening dimension for the Power Post 
  • The amount of exposed  threaded rod  does not affect the capacity of the post as long as it is fully threaded into the bearing nut
Regina_fabrication_shop

Let’s Work Together

Ready to start your next project? Work with a steel partner you can trust.

Get a Quote: Saskatoon Get a Quote: Regina